Quantifying variabilities in cardiac digital twin models of the electrocardiogram (2407.17146v2)

Published 24 Jul 2024 in physics.med-ph, cs.NA, math.NA, and q-bio.TO

Abstract: Cardiac digital twins (CDTs) of human cardiac electrophysiology (EP) are digital replicas of patient hearts that match like-for-like clinical observations. The electrocardiogram (ECG), as the most prevalent non-invasive observation of cardiac electrophysiology, is considered an ideal target for CDT calibration. Recent advanced CDT calibration methods have demonstrated their ability to minimize discrepancies between simulated and measured ECG signals, effectively replicating all key morphological features relevant to diagnostics. However, due to the inherent nature of clinical data acquisition and CDT model generation pipelines, discrepancies inevitably arise between the real physical electrophysiology in a patient and the simulated virtual electrophysiology in a CDT. In this study, we aim to qualitatively and quantitatively analyze the impact of these uncertainties on ECG morphology and diagnostic markers. We analyze residual beat-to-beat variability in ECG recordings obtained from healthy subjects and patients. Using a biophysically detailed and anatomically accurate computational model of whole-heart electrophysiology combined with a detailed torso model calibrated to closely replicate measured ECG signals, we vary anatomical factors (heart location, orientation, size), heterogeneity in electrical conductivities in the heart and torso, and electrode placements across ECG leads to assess their qualitative impact on ECG morphology. Our study demonstrates that diagnostically relevant ECG features and overall morphology appear relatively robust against the investigated uncertainties. This resilience is consistent with the narrow distribution of ECG due to residual beat-to-beat variability observed in both healthy subjects and patients.

Citations (2)
List To Do Tasks Checklist Streamline Icon: https://streamlinehq.com

Collections

Sign up for free to add this paper to one or more collections.

Summary

We haven't generated a summary for this paper yet.

Dice Question Streamline Icon: https://streamlinehq.com

Follow-Up Questions

We haven't generated follow-up questions for this paper yet.

X Twitter Logo Streamline Icon: https://streamlinehq.com