Identifying Secure Operating Ranges for DER Control using Bilevel Optimization (2309.00625v1)

Published 28 Jun 2023 in eess.SY, cs.SY, and math.OC

Abstract: Active distribution grids are accommodating an increasing number of controllable electric loads and distributed energy resources (DERs). A majority of these DERs are managed by entities other than the distribution utility, such as individual customers or third-party aggregators, who control the loads and DERs without consideration of any distribution grid constraints. This makes it challenging for a distribution system operator (DSO) to allow third-party aggregators and transmission operators to fully exploit the flexibility offered by these resources while also ensuring that distribution grid constraints such as voltage magnitude limits are not violated. In this paper, we develop a bilevel optimization-based framework to determine the aggregate power flexibility that can be obtained from an unbalanced distribution grid while ensuring that there is no disaggregation solution that leads to grid constraint violations. The results are a set of constraints and operating rules that are easy to communicate, and which provide the entities that procure flexibility from DERs (e.g. transmission operators or third-party aggregators) with the ability to freely implement their own disaggregation strategy without intervention from the DSO. The proposed approach is tested on two unbalanced distribution feeders and our simulation results indicate that it is possible to determine a wide range of aggregate power flexibility, as long as a simple set of rules for DER control activation are followed.

Citations (4)

Summary

We haven't generated a summary for this paper yet.

List To Do Tasks Checklist Streamline Icon: https://streamlinehq.com

Collections

Sign up for free to add this paper to one or more collections.

Lightbulb On Streamline Icon: https://streamlinehq.com

Continue Learning

We haven't generated follow-up questions for this paper yet.

Don't miss out on important new AI/ML research

See which papers are being discussed right now on X, Reddit, and more:

“Emergent Mind helps me see which AI papers have caught fire online.”

Philip

Philip

Creator, AI Explained on YouTube