Papers
Topics
Authors
Recent
Detailed Answer
Quick Answer
Concise responses based on abstracts only
Detailed Answer
Well-researched responses based on abstracts and relevant paper content.
Custom Instructions Pro
Preferences or requirements that you'd like Emergent Mind to consider when generating responses
Gemini 2.5 Flash
Gemini 2.5 Flash 39 tok/s
Gemini 2.5 Pro 49 tok/s Pro
GPT-5 Medium 12 tok/s Pro
GPT-5 High 18 tok/s Pro
GPT-4o 91 tok/s Pro
Kimi K2 191 tok/s Pro
GPT OSS 120B 456 tok/s Pro
Claude Sonnet 4 37 tok/s Pro
2000 character limit reached

Robustness of an Artificial Intelligence Solution for Diagnosis of Normal Chest X-Rays (2209.09204v1)

Published 31 Aug 2022 in eess.IV and cs.AI

Abstract: Purpose: AI solutions for medical diagnosis require thorough evaluation to demonstrate that performance is maintained for all patient sub-groups and to ensure that proposed improvements in care will be delivered equitably. This study evaluates the robustness of an AI solution for the diagnosis of normal chest X-rays (CXRs) by comparing performance across multiple patient and environmental subgroups, as well as comparing AI errors with those made by human experts. Methods: A total of 4,060 CXRs were sampled to represent a diverse dataset of NHS patients and care settings. Ground-truth labels were assigned by a 3-radiologist panel. AI performance was evaluated against assigned labels and sub-groups analysis was conducted against patient age and sex, as well as CXR view, modality, device manufacturer and hospital site. Results: The AI solution was able to remove 18.5% of the dataset by classification as High Confidence Normal (HCN). This was associated with a negative predictive value (NPV) of 96.0%, compared to 89.1% for diagnosis of normal scans by radiologists. In all AI false negative (FN) cases, a radiologist was found to have also made the same error when compared to final ground-truth labels. Subgroup analysis showed no statistically significant variations in AI performance, whilst reduced normal classification was observed in data from some hospital sites. Conclusion: We show the AI solution could provide meaningful workload savings by diagnosis of 18.5% of scans as HCN with a superior NPV to human readers. The AI solution is shown to perform well across patient subgroups and error cases were shown to be subjective or subtle in nature.

Citations (2)

Summary

We haven't generated a summary for this paper yet.

List To Do Tasks Checklist Streamline Icon: https://streamlinehq.com

Collections

Sign up for free to add this paper to one or more collections.

Lightbulb On Streamline Icon: https://streamlinehq.com

Continue Learning

We haven't generated follow-up questions for this paper yet.