Papers
Topics
Authors
Recent
Detailed Answer
Quick Answer
Concise responses based on abstracts only
Detailed Answer
Well-researched responses based on abstracts and relevant paper content.
Custom Instructions Pro
Preferences or requirements that you'd like Emergent Mind to consider when generating responses
Gemini 2.5 Flash
Gemini 2.5 Flash 77 tok/s
Gemini 2.5 Pro 33 tok/s Pro
GPT-5 Medium 25 tok/s Pro
GPT-5 High 27 tok/s Pro
GPT-4o 75 tok/s Pro
Kimi K2 220 tok/s Pro
GPT OSS 120B 465 tok/s Pro
Claude Sonnet 4 36 tok/s Pro
2000 character limit reached

Model Order Reduction of The Time-Dependent Advection-Diffusion-Reaction Equation with Time-Varying Coefficients: Application to Real-Time Water Quality Monitoring (2201.01546v2)

Published 5 Jan 2022 in eess.SY and cs.SY

Abstract: Advection-Diffusion-Reaction (ADR) Partial Differential Equations (PDEs) appear in a wide spectrum of applications such as chemical reactors, concentration flows, and biological systems. A large number of these applications require the solution of ADR equations involving time-varying coefficients, where analytical solutions are usually intractable. Numerical solutions on the other hand require fine discretization and are computationally very demanding. Consequently, the models are normally not suitable for real-time monitoring and control purposes. In this contribution, a reduced order modeling method for a general ADR system with time-varying coefficients is proposed. Optimality of the reduced order model regarding the reduction induced error is achieved by using an H2-norm reduction method. The efficacy of the method is demonstrated using two test cases. Namely, a case for an ADR with arbitrary dynamics varying coefficients and a second case including the modeling of an exemplary water quality distribution path with randomly generated demand. The reduced order models are evaluated against high fidelity simulations using MATLAB's finite element method PDE toolbox. It is shown that the reduction can achieve a significant computational speedup allowing for the usage of the model for real-time applications with sampling times in milliseconds range. Moreover, the constructed ROM is shown to achieve high prediction accuracy with the normalized mean square error below 2.3 % for a real-world water quality simulation test case.

Citations (1)
List To Do Tasks Checklist Streamline Icon: https://streamlinehq.com

Collections

Sign up for free to add this paper to one or more collections.

Summary

We haven't generated a summary for this paper yet.

Dice Question Streamline Icon: https://streamlinehq.com

Follow-Up Questions

We haven't generated follow-up questions for this paper yet.