Papers
Topics
Authors
Recent
Detailed Answer
Quick Answer
Concise responses based on abstracts only
Detailed Answer
Well-researched responses based on abstracts and relevant paper content.
Custom Instructions Pro
Preferences or requirements that you'd like Emergent Mind to consider when generating responses
Gemini 2.5 Flash
Gemini 2.5 Flash 37 tok/s
Gemini 2.5 Pro 41 tok/s Pro
GPT-5 Medium 10 tok/s Pro
GPT-5 High 15 tok/s Pro
GPT-4o 84 tok/s Pro
Kimi K2 198 tok/s Pro
GPT OSS 120B 448 tok/s Pro
Claude Sonnet 4 31 tok/s Pro
2000 character limit reached

Deep Learning Adapted Acceleration for Limited-view Photoacoustic Computed Tomography (2111.05194v1)

Published 8 Nov 2021 in eess.IV and cs.CV

Abstract: Photoacoustic imaging (PAI) is a non-invasive imaging modality that detects the ultrasound signal generated from tissue with light excitation. Photoacoustic computed tomography (PACT) uses unfocused large-area light to illuminate the target with ultrasound transducer array for PA signal detection. Limited-view issue could cause a low-quality image in PACT due to the limitation of geometric condition. The model-based method is used to resolve this problem, which contains different regularization. To adapt fast and high-quality reconstruction of limited-view PA data, in this paper, a model-based method that combines the mathematical variational model with deep learning is proposed to speed up and regularize the unrolled procedure of reconstruction. A deep neural network is designed to adapt the step of the gradient updated term of data consistency in the gradient descent procedure, which can obtain a high-quality PA image only with a few iterations. Note that all parameters and priors are automatically learned during the offline training stage. In experiments, we show that this method outperforms the other methods with half-view (180 degrees) simulation and real data. The comparison of different model-based methods show that our proposed scheme has superior performances (over 0.05 for SSIM) with same iteration (3 times) steps. Furthermore, an unseen data is used to validate the generalization of different methods. Finally, we find that our method obtains superior results (0.94 value of SSIM for in vivo) with a high robustness and accelerated reconstruction.

Citations (6)

Summary

We haven't generated a summary for this paper yet.

List To Do Tasks Checklist Streamline Icon: https://streamlinehq.com

Collections

Sign up for free to add this paper to one or more collections.

Lightbulb On Streamline Icon: https://streamlinehq.com

Continue Learning

We haven't generated follow-up questions for this paper yet.