Papers
Topics
Authors
Recent
Assistant
AI Research Assistant
Well-researched responses based on relevant abstracts and paper content.
Custom Instructions Pro
Preferences or requirements that you'd like Emergent Mind to consider when generating responses.
Gemini 2.5 Flash
Gemini 2.5 Flash 135 tok/s
Gemini 2.5 Pro 48 tok/s Pro
GPT-5 Medium 27 tok/s Pro
GPT-5 High 28 tok/s Pro
GPT-4o 80 tok/s Pro
Kimi K2 181 tok/s Pro
GPT OSS 120B 439 tok/s Pro
Claude Sonnet 4.5 35 tok/s Pro
2000 character limit reached

Rotation-constrained optical see-through headset calibration withbare-hand alignment (2108.10603v1)

Published 24 Aug 2021 in cs.GT and cs.GR

Abstract: The inaccessibility of user-perceived reality remains an open issue in pursuing the accurate calibration of optical see-through (OST) head-mounted displays (HMDs). Manual user alignment is usually required to collect a set of virtual-to-real correspondences, so that a default or an offline display calibration can be updated to account for the user's eye position(s). Current alignment-based calibration procedures usually require point-wise alignments between rendered image point(s) and associated physical landmark(s) of a target calibration tool. As each alignment can only provide one or a few correspondences, repeated alignments are required to ensure calibration quality. This work presents an accurate and tool-less online OST calibration method to update an offline-calibrated eye-display model. The user's bare hand is markerlessly tracked by a commercial RGBD camera anchored to the OST headset to generate a user-specific cursor for correspondence collection. The required alignment is object-wise, and can provide thousands of unordered corresponding points in tracked space. The collected correspondences are registered by a proposed rotation-constrained iterative closest point (rcICP) method to optimise the viewpoint-related calibration parameters. We implemented such a method for the Microsoft HoloLens 1. The resiliency of the proposed procedure to noisy data was evaluated through simulated tests and real experiments performed with an eye-replacement camera. According to the simulation test, the rcICP registration is robust against possible user-induced rotational misalignment. With a single alignment, our method achieves 8.81 arcmin (1.37 mm) positional error and 1.76 degree rotational error by camera-based tests in the arm-reach distance, and 10.79 arcmin (7.71 pixels) reprojection error by user tests.

Citations (6)

Summary

We haven't generated a summary for this paper yet.

Dice Question Streamline Icon: https://streamlinehq.com

Open Problems

We haven't generated a list of open problems mentioned in this paper yet.

Lightbulb Streamline Icon: https://streamlinehq.com

Continue Learning

We haven't generated follow-up questions for this paper yet.

List To Do Tasks Checklist Streamline Icon: https://streamlinehq.com

Collections

Sign up for free to add this paper to one or more collections.