Papers
Topics
Authors
Recent
Detailed Answer
Quick Answer
Concise responses based on abstracts only
Detailed Answer
Well-researched responses based on abstracts and relevant paper content.
Custom Instructions Pro
Preferences or requirements that you'd like Emergent Mind to consider when generating responses
Gemini 2.5 Flash
Gemini 2.5 Flash 37 tok/s
Gemini 2.5 Pro 41 tok/s Pro
GPT-5 Medium 10 tok/s Pro
GPT-5 High 15 tok/s Pro
GPT-4o 84 tok/s Pro
Kimi K2 198 tok/s Pro
GPT OSS 120B 448 tok/s Pro
Claude Sonnet 4 31 tok/s Pro
2000 character limit reached

Interactive Power to Frequency Dynamics Between Grid-Forming Inverters and Synchronous Generators in Power Electronics-Dominated Power Systems (2102.12332v4)

Published 24 Feb 2021 in eess.SY and cs.SY

Abstract: With increased attention on grid-forming inverters as a power system stabilizing device during periods of high shares of inverter-based resource operations, there is a present need for a transparent and rigorous investigation of the inverted and direct power to frequency control capabilities, and associated impacts, of these devices on hybrid systems. Here, analysis of the frequency dynamics of the droop controlled grid-forming inverter and the synchronous generator illuminates the inverted active power-frequency relationship and the frequency response order reduction, forming the basis for novel, non-linear frequency droop control approaches. Device-level electromagnetic transient domain simulations corroborate the order-reduction findings, establish that a properly designed DC-side system has a negligible dynamical impact on active power transfer and will not impede frequency regulation, and confirm the frequency response improvement with non-linear control. Simulations of the 9- and 39-bus test systems validate the order reduction and associated decoupling of the nadir and rate of change of frequency in large networks. The primary system oscillatory mode confirms the correlation between high shares of grid-forming inverters and increased mode frequency and damping; a sharp decrease in damping is observed at shares above 80%, whether by grid-forming device quantity in large networks or rating variations in a small test system. Finally, simulation results on the Hawaiian island of Maui show a trend towards a first order frequency response with a grid-forming inverter, further corroborating the analytic findings and network impacts.

Citations (4)

Summary

We haven't generated a summary for this paper yet.

List To Do Tasks Checklist Streamline Icon: https://streamlinehq.com

Collections

Sign up for free to add this paper to one or more collections.

Lightbulb On Streamline Icon: https://streamlinehq.com

Continue Learning

We haven't generated follow-up questions for this paper yet.