Papers
Topics
Authors
Recent
Gemini 2.5 Flash
Gemini 2.5 Flash
97 tokens/sec
GPT-4o
53 tokens/sec
Gemini 2.5 Pro Pro
44 tokens/sec
o3 Pro
5 tokens/sec
GPT-4.1 Pro
47 tokens/sec
DeepSeek R1 via Azure Pro
28 tokens/sec
2000 character limit reached

Motion Correction of 3D Dynamic Contrast-Enhanced Ultrasound Imaging without Anatomical Bmode Images (2010.01721v1)

Published 5 Oct 2020 in eess.IV

Abstract: In conventional 2D DCE-US, motion correction algorithms take advantage of accompanying side-by-side anatomical Bmode images that contain time-stable features. However, current commercial models of 3D DCE-US do not provide side-by-side Bmode images, which makes motion correction challenging. This work introduces a novel motion correction (MC) algorithm for 3D DCE-US and assesses its efficacy when handling clinical data sets. In brief, the algorithm uses a pyramidal approach whereby short temporal windows consisting of 3-6 consecutive frames are created to perform local registrations, which are then registered to a master reference derived from a weighted average of all frames. We evaluated the algorithm in 8 patients with metastatic lesions in the liver using the Philips X6-1 matrix transducer at a frame rate of 1-3 Hz. We assessed improvements in original vs. motion corrected 3D DCE-US cine using: i) frame-to-frame volumetric overlap of segmented lesions, ii) normalized correlation coefficient (NCC) between frames (similarity analysis), and iii) sum of squared errors (SSE), root-mean-squared error (RMSE), and r-squared (R2) quality-of-fit from fitted time-intensity curves (TIC) extracted from a segmented lesion. Overall, results demonstrate significant decreases in 3D DCE-US motion after applying the proposed algorithm. We noted significant improvements in frame-to-frame lesion overlap across all patients, from 68% without correction to 83% with motion correction (p = 0.023). Frame-to-frame similarity as assessed by NCC also significantly improved on two different sets of time points from 0.694 (original cine) to 0.862 (corresponding MC cine) and 0.723 to 0.886. TIC analysis displayed a significant decrease in RMSE (p = 0.018) and a significant increase in R2 goodness-of-fit (p = 0.029) for the patient cohort.

User Edit Pencil Streamline Icon: https://streamlinehq.com
Authors (8)
  1. Jia-Shu Chen (1 paper)
  2. Maged Goubran Ph. D. (1 paper)
  3. Gaeun Kim (5 papers)
  4. Jurgen K. Willmann M. D. (1 paper)
  5. Michael Zeineh M. D. (1 paper)
  6. Dimitre Hristov Ph. D. (1 paper)
  7. Ahmed El Kaffas Ph. D (1 paper)
  8. Ph. D. (17 papers)
Citations (1)

Summary

We haven't generated a summary for this paper yet.