Papers
Topics
Authors
Recent
Detailed Answer
Quick Answer
Concise responses based on abstracts only
Detailed Answer
Well-researched responses based on abstracts and relevant paper content.
Custom Instructions Pro
Preferences or requirements that you'd like Emergent Mind to consider when generating responses
Gemini 2.5 Flash
Gemini 2.5 Flash 94 tok/s
Gemini 2.5 Pro 44 tok/s Pro
GPT-5 Medium 30 tok/s Pro
GPT-5 High 35 tok/s Pro
GPT-4o 120 tok/s Pro
Kimi K2 162 tok/s Pro
GPT OSS 120B 470 tok/s Pro
Claude Sonnet 4 39 tok/s Pro
2000 character limit reached

Synthetic multi-focus optical-resolution photoacoustic microscope for large volumetric imaging (2009.03689v1)

Published 7 Sep 2020 in eess.IV and physics.med-ph

Abstract: Photoacoustic microscopy is becoming an important tool for the biomedical research. It has been widely used in biological researches, such as structural imaging of vasculature, brain structural and functional imaging, and tumor detection. The conventional optical-resolution photoacoustic microscopy (OR- PAM) employs focused gaussian beam to achieve high lateral resolution by a microscope objective with high numerical apertures. Since the focused gaussian beam only has narrow depth range in focus, little detail in depth direction can be revealed. Here, we developed a synthetic multi-focus optical-resolution photoacoustic microscope using multi-scale weighted gradient-based fusion. Based on the saliency of the image structure, a gradient-based multi-focus image fusion method is used, and a multi-scale method is used to determine the gradient weights. We pay special attention to a dual-scale scheme, which effectively solves the fusion problem caused by anisotropic blur and registration error. First, the structure-based large-scale focus measurement method is used to reduce the effect of anisotropic blur and registration error on the detection of the focus area, and then the gradient weights near the edge wave are used by applying the small-scale focus measure. Simulation was performed to test the performance of our method, different focused images were used to verify the feasibility of the method. Performance of our method was analyzed by calculating Entropy, Mean Square Error (MSE) and Edge strength. The result of simulation shown that this method can extend the depth of field of PAM two times without the sacrifice of lateral resolution. And the in vivo imaging of the zebra fish further demonstrates the feasibility of our method.

List To Do Tasks Checklist Streamline Icon: https://streamlinehq.com

Collections

Sign up for free to add this paper to one or more collections.

Summary

We haven't generated a summary for this paper yet.

Dice Question Streamline Icon: https://streamlinehq.com

Follow-Up Questions

We haven't generated follow-up questions for this paper yet.