Papers
Topics
Authors
Recent
Detailed Answer
Quick Answer
Concise responses based on abstracts only
Detailed Answer
Well-researched responses based on abstracts and relevant paper content.
Custom Instructions Pro
Preferences or requirements that you'd like Emergent Mind to consider when generating responses
Gemini 2.5 Flash
Gemini 2.5 Flash 37 tok/s
Gemini 2.5 Pro 44 tok/s Pro
GPT-5 Medium 14 tok/s Pro
GPT-5 High 14 tok/s Pro
GPT-4o 90 tok/s Pro
Kimi K2 179 tok/s Pro
GPT OSS 120B 462 tok/s Pro
Claude Sonnet 4 37 tok/s Pro
2000 character limit reached

Multi-stage Power Scheduling Framework for Data Center with Chilled Water Storage in Energy and Regulation Markets (2007.09770v1)

Published 19 Jul 2020 in eess.SY and cs.SY

Abstract: Leveraging electrochemical and thermal energy storage systems has been proposed as a strategy to reduce peak power in data centers. Thermal energy storage systems, such as chilled water tanks, have gained increasing attention in data centers for load shifting due to their relatively small capital and operational costs compared to electrochemical energy storage. However, there are few studies investigating the possibility of utilizing thermal energy storage system with resources to provide ancillary services (e.g., frequency regulation) to the grid. This paper proposes a synergistic control strategy for the data center with a chilled water storage providing frequency regulation service by adjusting the chiller capacity, storage charging rate, and IT server CPU frequency. Then, a three-stage multi-market scheduling framework based on a model predictive control scheme is developed to minimize operational costs of data centers participating in both energy and regulation markets. The framework solves a power baseline scheduling problem, a regulation reserve problem, and a real-time power signal tracking problem sequentially. Simulation results show that utilizing the thermal energy storage can increase the regulation capacity bid, reduce energy costs and demand charges, and also harvest frequency regulation revenues. The proposed multi-market scheduling framework in a span of two days can reduce the operational costs up to 8.8% ($1,606.4) compared to the baseline with 0.2% (\$38.7) energy cost reduction, 6.5% (\$1,179.4) from demand reduction, and 2.1% (\$338.3) from regulation revenues.

List To Do Tasks Checklist Streamline Icon: https://streamlinehq.com

Collections

Sign up for free to add this paper to one or more collections.

Summary

We haven't generated a summary for this paper yet.

Dice Question Streamline Icon: https://streamlinehq.com

Follow-Up Questions

We haven't generated follow-up questions for this paper yet.