Papers
Topics
Authors
Recent
Detailed Answer
Quick Answer
Concise responses based on abstracts only
Detailed Answer
Well-researched responses based on abstracts and relevant paper content.
Custom Instructions Pro
Preferences or requirements that you'd like Emergent Mind to consider when generating responses
Gemini 2.5 Flash
Gemini 2.5 Flash 48 tok/s
Gemini 2.5 Pro 48 tok/s Pro
GPT-5 Medium 26 tok/s Pro
GPT-5 High 19 tok/s Pro
GPT-4o 107 tok/s Pro
Kimi K2 205 tok/s Pro
GPT OSS 120B 473 tok/s Pro
Claude Sonnet 4 37 tok/s Pro
2000 character limit reached

A novel 3D multi-path DenseNet for improving automatic segmentation of glioblastoma on pre-operative multi-modal MR images (2005.04901v1)

Published 11 May 2020 in physics.med-ph and eess.IV

Abstract: Convolutional neural networks have achieved excellent results in automatic medical image segmentation. In this study, we proposed a novel 3D multi-path DenseNet for generating the accurate glioblastoma (GBM) tumor contour from four multi-modal pre-operative MR images. We hypothesized that the multi-path architecture could achieve more accurate segmentation than a single-path architecture. 258 GBM patients were included in this study. Each patient had four MR images (T1-weighted, contrast-enhanced T1-weighted, T2-weighted, and FLAIR) and the manually segmented tumor contour. We built a 3D multi-path DenseNet that could be trained to generate the corresponding GBM tumor contour from the four MR images. A 3D single-path DenseNet was also built for comparison. Both DenseNets were based on the encoder-decoder architecture. All four images were concatenated and fed into a single encoder path in the single-path DenseNet, while each input image had its own encoder path in the multi-path DenseNet. The patient cohort was randomly split into a training set of 180 patients, a validation set of 39 patients, and a testing set of 39 patients. Model performance was evaluated using the Dice similarity coefficient (DSC), average surface distance (ASD), and 95% Hausdorff distance (HD95%). Wilcoxon signed-rank tests were conducted to examine the model differences. The single-path DenseNet achieved a DSC of 0.911$\pm$0.060, ASD of 1.3$\pm$0.7 mm, and HD95% of 5.2$\pm$7.1 mm, while the multi-path DenseNet achieved a DSC of 0.922$\pm$0.041, ASD of 1.1$\pm$0.5 mm, and HD95% of 3.9$\pm$3.3 mm. The p-values of all Wilcoxon signed-rank tests were less than 0.05. Both 3D DenseNets generated GBM tumor contours in good agreement with the manually segmented contours from multi-modal MR images. The multi-path DenseNet achieved more accurate tumor segmentation than the single-path DenseNet.

Summary

We haven't generated a summary for this paper yet.

List To Do Tasks Checklist Streamline Icon: https://streamlinehq.com

Collections

Sign up for free to add this paper to one or more collections.

Lightbulb On Streamline Icon: https://streamlinehq.com

Continue Learning

We haven't generated follow-up questions for this paper yet.