Papers
Topics
Authors
Recent
Detailed Answer
Quick Answer
Concise responses based on abstracts only
Detailed Answer
Well-researched responses based on abstracts and relevant paper content.
Custom Instructions Pro
Preferences or requirements that you'd like Emergent Mind to consider when generating responses
Gemini 2.5 Flash
Gemini 2.5 Flash 82 tok/s
Gemini 2.5 Pro 52 tok/s Pro
GPT-5 Medium 19 tok/s Pro
GPT-5 High 17 tok/s Pro
GPT-4o 107 tok/s Pro
Kimi K2 174 tok/s Pro
GPT OSS 120B 468 tok/s Pro
Claude Sonnet 4 37 tok/s Pro
2000 character limit reached

Evaluation of an AI System for the Detection of Diabetic Retinopathy from Images Captured with a Handheld Portable Fundus Camera: the MAILOR AI study (1908.06399v1)

Published 18 Aug 2019 in eess.IV and cs.CV

Abstract: Objectives: To evaluate the performance of an AI system (Pegasus, Visulytix Ltd., UK), at the detection of Diabetic Retinopathy (DR) from images captured by a handheld portable fundus camera. Methods: A cohort of 6,404 patients (~80% with diabetes mellitus) was screened for retinal diseases using a handheld portable fundus camera (Pictor Plus, Volk Optical Inc., USA) at the Mexican Advanced Imaging Laboratory for Ocular Research. The images were graded for DR by specialists according to the Scottish DR grading scheme. The performance of the AI system was evaluated, retrospectively, in assessing Referable DR (RDR) and Proliferative DR (PDR) and compared to the performance on a publicly available desktop camera benchmark dataset. Results: For RDR detection, Pegasus performed with an 89.4% (95% CI: 88.0-90.7) Area Under the Receiver Operating Characteristic (AUROC) curve for the MAILOR cohort, compared to an AUROC of 98.5% (95% CI: 97.8-99.2) on the benchmark dataset. This difference was statistically significant. Moreover, no statistically significant difference was found in performance for PDR detection with Pegasus achieving an AUROC of 94.3% (95% CI: 91.0-96.9) on the MAILOR cohort and 92.2% (95% CI: 89.4-94.8) on the benchmark dataset. Conclusions: Pegasus showed good transferability for the detection of PDR from a curated desktop fundus camera dataset to real-world clinical practice with a handheld portable fundus camera. However, there was a substantial, and statistically significant, decrease in the diagnostic performance for RDR when using the handheld device.

Citations (37)
List To Do Tasks Checklist Streamline Icon: https://streamlinehq.com

Collections

Sign up for free to add this paper to one or more collections.

Summary

We haven't generated a summary for this paper yet.

Dice Question Streamline Icon: https://streamlinehq.com

Follow-Up Questions

We haven't generated follow-up questions for this paper yet.