Mechanomyography based closed-loop Functional Electrical Stimulation cycling system (1807.11241v1)

Published 30 Jul 2018 in cs.RO

Abstract: Functional Electrical Stimulation (FES) systems are successful in restoring motor function and supporting paralyzed users. Commercially available FES products are open loop, meaning that the system is unable to adapt to changing conditions with the user and their muscles which results in muscle fatigue and poor stimulation protocols. This is because it is difficult to close the loop between stimulation and monitoring of muscle contraction using adaptive stimulation. FES causes electrical artefacts which make it challenging to monitor muscle contractions with traditional methods such as electromyography (EMG). We look to overcome this limitation by combining FES with novel mechanomyographic (MMG) sensors to be able to monitor muscle activity during stimulation in real time. To provide a meaningful task we built an FES cycling rig with a software interface that enabled us to perform adaptive recording and stimulation, and then combine this with sensors to record forces applied to the pedals using force sensitive resistors (FSRs), crank angle position using a magnetic incremental encoder and inputs from the user using switches and a potentiometer. We illustrated this with a closed-loop stimulation algorithm that used the inputs from the sensors to control the output of a programmable RehaStim 1 FES stimulator (Hasomed) in real-time. This recumbent bicycle rig was used as a testing platform for FES cycling. The algorithm was designed to respond to a change in requested speed (RPM) from the user and change the stimulation power (% of maximum current mA) until this speed was achieved and then maintain it.

Citations (6)

Summary

We haven't generated a summary for this paper yet.

Lightbulb Streamline Icon: https://streamlinehq.com

Continue Learning

We haven't generated follow-up questions for this paper yet.

List To Do Tasks Checklist Streamline Icon: https://streamlinehq.com

Collections

Sign up for free to add this paper to one or more collections.