Robotic Arm for Remote Surgery (1307.5641v1)

Published 22 Jul 2013 in cs.RO

Abstract: Recent advances in telecommunications have enabled surgeons to operate remotely on patients with the use of robotics. The investigation and testing of remote surgery using a robotic arm is presented. The robotic arm is designed to have four degrees of freedom that track the surgeon's x, y, z positions and the rotation angle of the forearm {\theta}. The system comprises two main subsystems viz. the detecting and actuating systems. The detection system uses infrared light-emitting diodes, a retroreflective bracelet and two infrared cameras which as a whole determine the coordinates of the surgeon's forearm. The actuation system, or robotic arm, is based on a lead screw mechanism which can obtain a maximum speed of 0.28 m/s with a 1.5 degree/step for the end-effector. The infrared detection and encoder resolutions are below 0.6 mm/pixel and 0.4 mm respectively, which ensures the robotic arm can operate precisely. The surgeon is able to monitor the patient with the use of a graphical user interface on the display computer. The lead screw system is modelled and compared to experimentation results. The system is controlled using a simple proportional-integrator (PI) control scheme which is implemented on a dSpace control unit. The control design results in a rise time of less than 0.5 s, a steady-state error of less than 1 mm and settling time of less than 1.4 s. The system accumulates, over an extended period of time, an error of approximately 4 mm due to inertial effects of the robotic arm. The results show promising system performance characteristics for a relatively inexpensive solution to a relatively advanced application.

Citations (1)

Summary

We haven't generated a summary for this paper yet.

Lightbulb Streamline Icon: https://streamlinehq.com

Continue Learning

We haven't generated follow-up questions for this paper yet.

List To Do Tasks Checklist Streamline Icon: https://streamlinehq.com

Collections

Sign up for free to add this paper to one or more collections.

Don't miss out on important new AI/ML research

See which papers are being discussed right now on X, Reddit, and more:

“Emergent Mind helps me see which AI papers have caught fire online.”

Philip

Philip

Creator, AI Explained on YouTube